  series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 1 of 10 north america only features: models single output model max output power (w) output voltage range (v) output current (a) input voltage (vac/hz) input voltage (vdc) mode of operation efficiency (%) 115 vac 230 vac 277 vac amer120-50250az 125 36-50 0-2.5 90-305/47-440 130-430 constant current 87 88 86 constant voltage 87 88 88 AMER120-36340AZ 122.4 24-36 0-3.4 90-305/47-440 130-430 constant current 87 88 88 constant voltage 87 88 88 amer120-24500az 120 12-24 0-5 90-305/47-440 130-430 constant current 85 86 87 constant voltage 86 86 87 add suffix ?-f? no dimming option ? exceeding the maximum output power wi ll permanently damage the converter. ????????????? ? the dimming feature is not supported when unit s are used in constant voltage mode only, aimtec suggests to order ?-f? no ???????????????????? dimming ? option in the case. ? in constant current mode output current is maximum shown, in constant voltage mode output voltage is the maximum shown. all mod els can be ordered with optional north american colour input wires (black (l), white (n), green (gnd)). add ??na? to part number wh en ordering. note: aimtec limited warranty of 5 years is valid based on product operation at dat asheet specifications at ambient temperature of 25c, humidity<75%, nominal input voltage (115/230/277vac) and at rated output load unless otherwise specified. see http://www.aimtec.com/terms-sale amer120-az?s ac/dc led drivers have electrical safeguards desig ned within to protect it from conventional electrical abnormalit ies with the levels listed in the safety table. applications for use within rural agricultural, heavy industrial, and other areas or re gions which are prone to ?dirty? electrical conditions which would subject any of the above models to excessive voltages surges or spikes, may damage or cause early life failure of product. in this case consideratio n should be made by the end user to ensure that adequate line or mains surge suppression is installed in front of aimtec device to ensure t he longevity of the products. failure to identify excessive line surges violations prior to installation may damage sensitive equipment permanently. input specifications parameters conditions typical maximum units current (full load) 115 vac 1800 ma 230 vac 800 ma 277 vac 700 ma inrush current <2ms (cold start) 115 vac 45 a 230 vac 60 a 277 vac 70 a leakage current i/o 0.25 ma i/fg, o/fg 3.5 ma power factor 115 vac 0.98 230 vac 0.94 277 vac 0.92 external fuse recommended slow blow type 3 a start-up time 900 ms ? ac-dc constant current or constant voltage led driver ? ? short circuit protection ? input range 90-305vac/47-440hz ? ? high efficiency up to 88% ? ? operating temperature -40 to 85c ? dimmable via resistive ? 5 years limited warranty click on series name for p roduct info on aimtec.com
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 2 of 10 north america only output specifications parameters conditions typical maximum units current accuracy 3 % line regulation ll-hl 2 % load regulation 0-100% load 3 % ripple & noise 20mhz bandwidth 150 mv p-p hold-up time 80 ms current adjustment range 100-10 % ripple and noise are measured at 20mhz bandwidth by using a 0.1 f (m/c) or (c/c) and 47f (e/c) parallel capacitor. note: from 0% to 10% dimming adjustment signal instability may be present. isolation specifications parameters conditions typical rated units tested voltage i/o 3sec 3750 vac i/fg 2000 vac o/fg 500 vac isolation resistance 500vdc >1000 m ? general specifications parameters conditions typical maximum units switching frequency 125 khz over current protection amer120-50250az 2.57 a AMER120-36340AZ 3.47 amer120-24500az 5.07 over voltage protection refer to constant current vs. constant voltage mode curve short circuit protection auto recovery operating temperature with derating over 55c refer to model application o c maximum case temperature 100 o c storage temperature -40 to +95 o c temperature coefficient 0.02 % / o c cooling free air convection humidity non condensing 20~95 % rh case material aluminum potting epoxy (ip68 rated) wires ul1015 18awg input & 14awg output *20cm weight 900 g dimensions (l x h x w) 181.00 x 59.00 x 47.00mm (7.13 x 2.32 x 1.85inches) mtbf >400,000 hrs (mil-hdbk-217f at t=+25c) safety specifications parameters agency approvals culus, ce standards ul8750, ul60950-1, en55022, class b, en60529(ip68), en61347-1, en61347-2-13 information technology equipment en55022 class b harmonic current emissions iec/en 61000-3-2, class c voltage fluctuations and flicker iec/en 61000-3-3, (en60555-3) electrostatic discharge immunity iec 61000-4-2 level 3 rf, electromagnetic field immunity iec 61000-4-3 level 2 electrical fast transient / burst immunity iec 61000-4-4 level 2 surge immunity iec 61000-4-5 level 3 rf, conducted disturbance immunity iec 61000-4-6 level 2 power frequency magnetic field immunity iec 61000-4-8 level 1 voltage dips, short interruptions immunity iec 61000-4-11
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 3 of 10 north america only dimensions wire connection: analog (resistive) dimming application circuit wire connection brown ac l blue ac n green ground red +v output black -v output blue (dimming) + vs dimming white (dimming) -vs dimming model number maximum pot value (k ? ) amer120-50250az 18.22 AMER120-36340AZ 22.10 amer120-24500az 34.31
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 4 of 10 north america only analog (0-10v) dimming a pplication circuit pwm (1khz) dimming application circuit derating
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 5 of 10 north america only efficiency vs. input voltage and output current (cc load) amer120-50250az AMER120-36340AZ
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 6 of 10 north america only efficiency vs. input voltage and output current (cc load) continued amer120-24500az pfc value vs. output load current (cc load) amer120-50250az
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 7 of 10 north america only pfc value vs. output load current (cc load) continued AMER120-36340AZ amer120-24500az
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 8 of 10 north america only constant current mode vs. constant voltage mode amer120-50250az AMER120-36340AZ
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 9 of 10 north america only constant current mode vs. constant voltage mode continued amer120-24500az output current vs. radj amer120-50250az
series amer120-az up to 5a | ac-dc / dc-dc | led driver / converter www.aimtec.com tel: +1 514 620 2722 toll free: + 1 888 9 aimtec (924 6832) f 052.1e r3.ad 10 of 10 north america only output current vs. radj continued AMER120-36340AZ amer120-24500az note: 1. datasheets are updated as needed and as such, specifications ar e subject to change without notic e. once printed or downloaded , datasheets are no longer controlled by aimtec; refer to www.aimtec.com for the most current product specifications. 2. product labels shown, including safety agency cert ifications on labels, may vary based on the date manufactured. 3. mechanical drawings and specifications are for reference only. 4. all specifications are measured at an am bient temperature of 25c, humidity<75%, nominal input voltage and at rated output load unless otherwise specifie d. 5. aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. cas numbers and other limited information are considered proprietary an d may not be available for release. 6. this product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control sys tems or other such applications which necessitate specific safety and regulatory standards ot her the ones listed in this datasheet. 7. warranty is in accordance with aimtec?s st andard terms of sale available at www.aimtec.com.


▲Up To Search▲   

 
Price & Availability of AMER120-36340AZ

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X